在线观看视频国产999_国产农村妇女一级毛片精品99_暖暖暖免费观看在线观看_精品国产午夜91_亚洲最大成人AV在线天堂网_成全高清在线观看免费高清_超碰在线观看网址_欧美亚洲牲夜夜综合久久_色哟哟免费视频播放网站_亚洲图片校园另激情类小说

PRODUCT

Getter Mercury Dispenser


      Features and Applications
        Getter Mercury Dispenser is used in devices that shall be filled with Mercury. The getter can not only release the Mercury needed but also sorb active gaseous impurities. The applying of Getter Mercury Dispenser does not have the pollution caused by the traditional Mercury-filling methods. Low-temperature mercury breathe in pharmaceutical bismuth, lead, tin low point metal and alloy that mercury form together. It's time and breathe in pharmaceutical characteristic for temperature low to clear up mercury, mercury vapour is force down , can prevent mercury from pollute. Apply to compact fluorescent lamp, neon lamp, etc. various kinds of need device to fill the mercury mainly.
    Basic Characteristics and General Data

    Banding gettering characteristic parameter

    Type

    Kind

    Amount of mercury
    cleared up of amount

    Specified content of aluminium of zirconium

    H6J8Q

    PIC1

    3 mg/cm

    -

    HZ6J8Q

    3 mg/cm

    10 mg/cm


    Tube gettering characteristic parameter

    Type

    Kind

    Amount of mercury
    cleared up of amount(mg)

    Specified content of aluminium of zirconium(mg)

    Size (mm)

    HZ4G2X

    PIC2

    2

    1.5

    φ1.0×4

    HZ4G4X

    4

    2.5

    φ1.5×4

    HZ6G6X

    6

    4.0

    φ1.5×6


    CCFL gettering characteristic parameter

    Type

    Amount of mercury
    cleared up of amount

    T(℃)

    ΔT(℃)

    P。(Pa)

    Remarks

    HBPS-1-X

    5.67%

    64

    52-120

    0.03

     

    HBPS-2-X

    10.71%

    64

    52-102

    0.03

     

    HBI-1-X

    5.67%

    81

    38-100

    0.09

    Can instead of Liquid Mercury Directly
    Need to Use with Auxiliary Amalgam

    HBI-2-X

    10.71%

    81

    38-85

    0.09

     


    P。-Hg vapour press
    T-The lowest working temperature
    ΔT-Temperature within the range of 90% of optimum value of the luminous flux.
    PIC1 Banding
    PIC2 Tube
    PIC3 Round annular to clear up mercury breathe in pharmaceutical lead

    Suggested Activation Conditions
        Getter Mercury Dispenser shall be activated by high frequency induced loop, laser or other means to release Mercury. Suggested activation conditions are 875±25℃ and 30s. If the activating can not reach 875℃, the time shall be prolonged to release the Mercury completely Low Temperature Amalgam should be activated before ageing so as to release partial mercury. The recommended activation conditions is 100℃×5 min.

    Caution
        When put in vacuum, Getter Mercury Dispenser begin to release Mercury around 500℃. Therefore, extra high temperature shall be avoided during the baking and exhaustion procedure lest the lost of Mercury.
        The low melting point amalgam shall be used in short time, and those that haven't used shall be kept in inert gas to prevent from surface oxidation and contamination. The temperature of the tube filled with low temperature amalgam getter shall be lower than 40℃ lest the amalgam agglomeration and effect amalgam fluidity and the loss of mercury. To ensure the heating temperature and time to get sufficient and stable mercury yield.
        Once the original packing has been opened, getter shall be used up soon and usually it shall not be exposed to the ambient atmosphere more than 24 hours. Prolonged storage of getter after the original packing has been opened shall be always in a dry atmosphere.

     

CN JP

Share

QQ
TEL

86-13512546708